HH2200--8800 ((rreevv.. 22)) LLIIQQUUIIDD CCOOOOLLIINNGG KKIITTSS TUTORIAL & INSTALLATION GUIDE
Figure 6 Figure 6 above illustrates a final installation, showing the MCR80-F2 radiator in place, the MCW6000 CPU cooler, the MCW50 VGA cooler, the M
Figure 6a Figure 6a shows a dual radiator setup. This particular setup was chosen to illustrate how to overcome the apparent difficulty of connectin
Available accessories Improve performance with a second radiator: MCR80-F2 Radiator assembly Part # MCR80-F2, includes radiator, 80mm fan, retention
Appendix: Individual Component Installation guides - INTENTIONNALY LEFT BLANK - Rouchon Industries, Inc., dbA Swiftec
MCR80 radiator 1 80mm fan guard 1 #6 X 1 1/4” Philips screw type B 4 80x80x25mm fan 1 #6 x 3/8” Philips screw type B 4 Quick-connect fittings
Using quick-connect fittings: If you are using soft vinyl tubing, you must also use the provided tube inserts: TIP! Rubbing the extremity of the tu
1. General Use The MCP650 pump is a magnetically driven centrifugal pump featuring a 12 V DC motor. It requires no maintenance when used with de-m
Connecting the pump to the circuit: The pump’s inlet and outlet are ½” in outside diameter. An adapter kit is available (included with all our comple
6. MCP650 – Exploded view Rouchon Industries, Inc., dbA Swiftech™ – 1703 E. 28th St, signal Hill, CA 90755, USA – T (562) 595-8009 – F (562) 595-
PARTS LIST – BARBED ADAPTERS ARE SOLD SEPARATELY Parts QTY PARTS QTY MCRES-525™ Reservoir 1 Retention screws 4 Fill-cap & o-ring 1 Port pl
Packing List Check-marked for applicable model and content Intel Pentium 4 socket 478 AMD Duron, Athlon, MP, XP socket 462 Intel Pentium 4 s
Installation guidelines Figure 1: Always leave sufficient slack in the lines to pull enough of the reservoir out of the drive bay and uncover the
Parts list Parts QTY PARTS QTY MCW6000-P™ water-block 1 Retention clips 2 Worm drive clamps 2 SP4 hold-down plate 1 1. Preparing your Motherb
3. Water-block installation: Step 1 Step 2 Step 3 Center the water-block inside the retention frame. Put both clips in place for the nex
Parts list Parts QTY PARTS QTY MCW6000-PX™ water-block 1 6-32 x 1 ¼” Philips screws 4 Worm drive clamps 2 Springs 4 SP4 hold-down plate 1 S
ASSEMBLY USING PLASTICFRAME AND SPRING CLIPSINCLUDED WITH MOTHERBOARD16 PART NO. DESCRIPTION1DUAL-XEON-BOARD Motherboard2 RETENTION Plastic retention
Using the spring-loaded screws and standoffs included with the water-block (fig. 1), or Using the plastic retention frames and spring slips inc
Parts QTY PARTS QTY MCW6000-NX™ water-block 1 6-32 x 7/8” Philips screws 4 Worm drive clamps 2 .600 x .250 Nylon spacer 4 SP4 hold-down plate
1. Preparing your Motherboard a. Remove the existing heat sink b. Carefully clean the CPU. c. Lightly coat the CPU with thermal compound. We recommend
Parts list Parts QTY PARTS QTY MCW6000-P™ water-block 1 3T spring/clip assemblies 2 Worm drive clamps 2 SK7 hold-down plate 1 This product i
1. Preparing your Motherboard a. Remove the existing heat sink b. Carefully clean the CPU. c. Lightly coat the CPU with thermal compound. We recommen
TTaabbllee ooff ccoonntteennttss TUBE ROUTING ...
Place the MCW6000-A over the CPU as shown in figure 1 page 1. The water-block step side MUST be located over the socket cam box. A label affixed
Parts QTY PARTS QTY MCW6000™ water-block 1 Spring loaded screw assemblies 2 Worm drive clamps 2 Sk8 hold-down plate 1 This product is inten
2. Water-block orientation For ease of operations during bleeding, the outlet should always be at the highest point (while system is standing upright
Rouchon Industries, Inc., dbA Swiftech™ – 1703 E. 28th St, signal Hill, CA 90755, USA – T (562) 595-8009 – F (562) 595-8769 – All content Copyright S
Rouchon Industries, Inc., dbA Swiftech™ – 1703 E. 28th St, signal Hill, CA 90755, USA – T (562) 595-8009 – F (562) 595-8769 – All content Copyright S
Common parts to both platforms Intel platform specific parts AMD platforms specific parts Part Qty Part Qty Part Qty MCW20 ™ assembly 1 Neo
Rouchon Industries, Inc., dbA Swiftech™ – 1703 E. 28th St, signal Hill, CA 90755, USA – T (562) 595-8009 – F (562) 595-8769 – All content Copyright S
Rouchon Industries, Inc., dbA Swiftech™ – 1703 E. 28th St, signal Hill, CA 90755, USA – T (562) 595-8009 – F (562) 595-8769 – All content Copyright S
Rouchon Industries, Inc., dbA Swiftech™ – 1703 E. 28th St, signal Hill, CA 90755, USA – T (562) 595-8009 – F (562) 595-8769 – All content Copyright S
4. CONNECTING THE WATER-BLOCK(S) TO THE COOLING CIRCUIT ... 27 5. ATTAC
Preamble Congratulations on your purchase of a Swiftech liquid cooling system! This kit has been designed to facilitate the installation of the com
TUBE ROUTING The following table contains examples on how to establish connections between the different elements of a cooling circuit based on multi
Installation of the cooling components The following is a typical sequence of components installation. Placement of the cooling components may vary d
5. Cutting the tubing, & connecting components Now that your mock-up installation is in place, it is time to cut segments of tubing and connect
8. Final installation Once your system has been tested for leaks, it is now time to proceed with the final installation. Assuming that you followed ou